EJCTS Click here to go to Siemens website
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Mahmoud Loubani
Govind Chetty
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Loubani, M.
Right arrow Articles by Leverment, J. N.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Loubani, M.
Right arrow Articles by Leverment, J. N.
Related Collections
Right arrow Esophagus - cancer
Right arrow Esophagus - other

Eur J Cardiothorac Surg 2002;22:161-162
© 2002 Elsevier Science NL


Letter to the Editor

Reply to Berrisford

Mahmoud Loubani*, Govind Chetty, Said Shawkat, Joeseph N. Leverment

Department of Cardiothoracic Surgery, Glenfield Hospital, Leicester, LE3 9QP, UK

* Corresponding author. Tel.: +44-116-2871-471; fax: +44-116-2502 449
e-mail: mahmoud.loubani{at}ntlworld.com

Dear Editor,

Thank you for giving us the opportunity to respond to the letter from Berrisford et al. and to answer the points raised.

We elected to use the intra-aortic balloon pump (IABP) in the reported patients [1] as a last resort in order to avoid the need for major surgical intervention. However, the success of this technique in dilating the oesophageal strictures combined with no morbidity or mortality, although admittedly in a small series, is certainly encouraging.

The pressure inside the balloon rises to a maximum of 300 mmHg (information supplied by Datascope) which is well within the pressure required to rupture a normal oesophagus [2] not that we are using the IABP in patients with normal oesophaguses. At that pressure, the pump alarms and the balloon stops inflating which acts as the safety mechanism we referred to in the original article [1]. Furthermore the pressure inside the balloon can be continuously measured by connecting a three way tap in the middle of the helium line and a manometer line from that point to a pressure transducer that will give a digital read out of the pressure inside the balloon as it inflates and deflates.

The electronically built in feed back mechanism allows a gradual increase in the pressure applied inside the balloon as the augmentation is increased. The application of hand held gauges are not any more sensitive and much more variable depending on the operator.

The fact that the authors obviously work in a stand alone thoracic surgery department rather than a combined cardiothoracic unit should not be used as a barrier to the use of IABP. Most units have both cardiac and thoracic surgery and therefore the balloon pumps are readily available. The cost of the balloons should be weighed against the complexity and increased risk of perforation in these selected patients if ordinary methods are used. Certainly not all units find this prohibitive.

The rigid oesophagoscope was used in our technique, as a port only and therefore added no extra risk of perforation. It was used to allow the introduction of the flexible oesophagoscope, the balloon and the contrast media. Another precaution in our technique is the use of screening during the procedure to confirm the position of the balloon prior to inflation and also to assess the success of the dilatation and integrity of the oesophagus at the end of the procedure.

The repeated dilatation with the rapid inflation and deflation of the balloon might be another advantage of this method resulting in the gradual dilation of the stricture. This might be a better approach for dilating the oesophagus rather than the sustained once off pressure from controlled radial expansion balloons.

We do not agree with Berrisford et al. and believe that the use of IABP should be considered as a viable option for the management of complex oesophageal strictures in the armamentarium of the Cardiothoracic Surgeon.

References

  1. Loubani M., Chetty G., Shawkat S., Leverment J.N. Oesophageal stictures: new indication for intra-aortic balloon pumps. Eur J Cardiothorac Surg 2001;20:1237-1239.[Abstract/Free Full Text]
  2. Burt C.A. Pneumatic rupture of the intestinal canal with experimental data showing mechanism of perforation and pressure required. Arch Surg 1931;22:875.




This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Mahmoud Loubani
Govind Chetty
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Loubani, M.
Right arrow Articles by Leverment, J. N.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Loubani, M.
Right arrow Articles by Leverment, J. N.
Related Collections
Right arrow Esophagus - cancer
Right arrow Esophagus - other


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS