Eur J Cardiothorac Surg 2002;22:249-254
© 2002 Elsevier Science NL
a Department of Cardio-vascular Surgery, Centre Hospitalier Universitaire Vaudois (CHUV), CH-1011 Lausanne, Switzerland
b Department of Anesthesiology, Centre Hospitalier Universitaire Vaudois (CHUV), CH-1011 Lausanne, Switzerland
Received 6 February 2002; received in revised form 12 April 2002; accepted 1 May 2002.
* Corresponding author. Tel.: +41-21-314-2313; fax: +41-21-314-2278
e-mail: xavier.mueller{at}chuv.hospvd.ch
| Abstract |
|---|
|
|
|---|
Key Words: Off-pump Coronary artery bypass Hemodynamics
| 1. Introduction |
|---|
|
|
|---|
In order to avoid hemodynamical compromise during coronary exposure and stabilization, we adopted a technique avoiding any compression on the heart chambers. The aim of this work is to study the hemodynamical profile observed with such a technique in a group of patients undergoing a triple bypass on the posterior, lateral and anterior wall, respectively.
| 2. Patients and methods |
|---|
|
|
|---|
2.2. Surgical technique
The heart is exposed through a sternotomy. The left internal thoracic artery (LITA) is harvested first and wrapped in a swab soaked with papaverine. The pericardium is incised longitudinally. At the level of the diaphragm, the pericardium is cut back at right angle: on the left side the incision is carried out till the apex of the heart in order to ensure a free movement of the latter during heart lifting, whereas on the right side the incision is restricted to the pleural reflection avoiding any extension in the right pericardium/pleura.
Then, the heart is elevated with one hand and a heavy monofilament suture (no. 1 Prolene, Ethicon, Somerville, NJ) is placed on the right side of the spine halfway between the level of the right inferior pulmonary vein and that of the inferior vena cava. The suture is passed through a half-folded swab (60 cm long and 10 cm wide) and snared down, bringing the folded end of the swab in close contact with the posterior pericardium. The basic principle of exposure is to pull on both limbs of the swab in a direction opposite to the target wall with the target artery located between both limbs. Once the appropriate exposure is obtained, each limb is fixed to the surgical drapes. Care is taken to avoid any wrapping of the limbs around the heart or any traction of the limbs across the heart, both of which may generate compression. The illustration of this principle for each wall is shown in Figs. 13 . When the heart is lifted to expose the lateral and posterior walls, it lies on its base like a pyramid and moves freely without any compression or distortion constraint.
|
|
|
The target anastomotic site is stabilized with a suction type stabilizer, the Octopus system (Medtronic Inc., Minneapolis, MN). During all the anastomoses, the coronary flow is maintained with an intracoronary shunt. LITA is used to bypass the left anterior descending artery (LAD) in all patients, while internal saphenous vein segments are used to bypass the other arteries. Proximal anastomoses to the ascending aorta are performed during a single aortic partial side-bite clamping period. Graft flow is assessed with a transit time flowmeter (Medi-Stim, Oslo, Norway). The main parameter used to evaluate an adequate flow is the pulsatility index. A value exceeding 5 is considered as an indication to refashion the anastomosis.
The distal anastomoses are always performed in the same sequence, starting with the posterior wall, then the lateral wall and lastly the anterior wall. Moreover, the successive anastomoses are performed without interruption: between the anastomoses, the arms of the swab are moved in order to expose directly the next target artery, without bringing back the heart to its resting position. For the right coronary artery territory, we basically favored an anastomosis on the right coronary branches on the posterior wall. This policy was dictated by the risk of arrhythmias such as an atrioventricular block during the occlusion of non-critical right coronary stenosis due to blood flow interruption of the AV node artery taking off at the crux. The indication to bypass the right coronary artery was limited to critical proximal stenosis or occlusion.
2.3. Anesthesia
Patients receive their usual medication including long-acting ß-blockers up to the morning of the intervention. Perioperative monitoring consists of a five-lead ECG, capillary pulse oximetry, end-tidal CO2 determination, invasive arterial blood pressure measurement, and right heart pressure measurement with a pulmonary artery catheter (Baxter Healthcare, Irvine, CA). Cardiac output measurements are performed using intermittent 10-ml boluses of dextrose 5% solution at a temperature of 1820 °C. A transesophageal echocardiography probe is inserted in order to record the segmental motion and the heart function during the operation.
The anesthetic technique consists of premedication with benzodiazepine, and induction with etomidate (0.3 ml/kg) and fentanyl (1820 µg/kg). Neuromuscular blockade is achieved with vencuronium (0.1 mg/kg). The lungs are ventilated to slight hypocapnia (PaCO2 3035 mmHg) with air and O2 (50%) and without positive end expiratory pressure. Anesthesia is maintained with isoflurane (11.5% inspired concentration). At skin incision, a continuous infusion of diltiazem (0.1 mg/kg per hour), without loading dose, is started and continued throughout the operation. After mobilization of the LITA and before mobilization of the heart, 1 mg/kg of heparin is administered with a target activated clotting time (ACT) between 250 and 300 s. Patient intravenous solutions are adjusted with colloid and lactated Ringer to maintain a pulmonary capillary wedge pressure between 15 and 20 mmHg. During the coronary procedure, a noradrenaline drip is initiated when necessary to maintain MAP >70 mmHg. Importantly, no ß-adrenergic inotrope is used in order to avoid any increase of myocardial O2 consumption. Before heart mobilization, an auricular pacemaker lead is inserted, and the pacemaker is switched on at a rate of 60/min, should the SvO2 drop to less than 65%. Blood loss is processed with a cell spinning device in all the cases. At the end of the procedure, 50 mg of protamine is administered if the ACT>300 s.
2.4. Hemodynamical monitoring and clinical data
The following hemodynamical parameters were analyzed: heart rate (HR), mean pulmonary arterial pressure (PAP), pulmonary capillary wedge pressure (PCWP), mean systemic arterial pressure (MAP), cardiac output index (COI) and central venous saturation (SvO2). The measurements were first recorded after the LITA harvest and before any surgical manipulation to expose and stabilize the target vessels, and then 10 min after the beginning of each grafting.
The following postoperative events were recorded: myocardial infarction defined as new Q wave and/or CK-MB>100IU/l, need for postoperative inotrope agents, supraventricular arrhythmias, pneumonia, neurological complications, renal failure (creatinine>120 µmol/l), and need for transfusion.
2.5. Statistics
Values recorded during the completion of each anastomosis were compared with those recorded at baseline using a t-test. Values were considered to differ significantly if P<0.05.
| 3. Results |
|---|
|
|
|---|
|
No patient received any intraoperative inotropic agent or intra-aortic balloon pump. Twenty patients required a noradrenaline drip to maintain MAP>70 mmHg, and four patients required atrial pacing. All patients received colloid as well as crystalloid solutions. The amounts were 850±230 ml and 2800±800 ml, respectively.
All of the hemodynamical recordings were able to be completed for the three grafts for all patients. One patient required a refashioning of a LITA-LAD anastomosis following unsatisfactory transit flowmeter measures, with a satisfactory result. Notably, once the heart was displaced with the arms of the swab, no adequate echocardiographic view could be obtained. The changes of each hemodynamical parameter are detailed in Tables 2 and 3.
|
|
| 4. Discussion |
|---|
|
|
|---|
The technique of exposure reported here is a modification of the single suture technique described by Ricci et al. [6]. Traction sutures were not applied because they lift the whole pericardial cavity, reducing the freedom of movement of the heart, which is required for subsequent manipulations. Nevertheless, several important points differ from the original technique [6]. Firstly, the stitch was placed on the right side of the spine in order to increase the lever arm when lifting the heart. Secondly, the traction on the arms of the swab was always applied away from the target wall, in other words the arms were never pulled across the heart in order to avoid any compression which may alter the geometry of the heart chambers leading to systolic and diastolic function compromise. With appropriate traction on both arms and adequate positioning of the operating table, a proper exposure of the lateral and posterior walls may be achieved without hemodynamical compromise, even for those difficult accessible arterial segments near the atrio-ventricular groove. Thirdly, no right pericardial/pleura incision, to allow partial herniation of the heart into the right chest as recommended [6], was necessary.
In keeping with this no compression philosophy, a suction-type stabilizer was used. It allows stabilization of the target artery with minimal compression effect in contrast to compression type system. In order to apply properly these exposure and stabilization techniques, it is important to stress that both should be used in a complementary fashion exclusively. Neither exposure technique should be used for stabilization, nor should stabilization technique be used for exposure. In the first case, the arms of the swab are used to stabilize the target area by wrapping them around the heart which may induce heart function compromise. In the second case, two complications may be anticipated. On the one hand, using the stabilizer as an exposure device can potentially damage the ventricular wall with the risk of severe bleeding. On the other hand, the stabilizer device itself leads to a distortion of the underlying and the adjacent heart chambers, and/or a compression of the underlying chamber according to the predominant forces applied by the stabilizer. Experimental studies fully support these hemodynamical concerns. Gründeman et al. [8] and Porat et al. [9] both used a suction stabilizer to displace the heart vertically in a porcine model by applying the device on the posterior wall. This procedure uniformly induced significant hemodynamical disturbance.
The use of intracoronary shunt belongs to the strategy of hemodynamical optimization. When dealing with ischemic heart disease, its seems logical to maintain intracoronary flow during the completion of the anastomosis in order to avoid any additional ischemic burden while the heart is not in its physiological position. Nevertheless, Gründeman et al. [14], in a porcine model, was able to restore coronary flow in the three coronary territories which were compromised while the heart was retracted by 90°, by increasing the preload with the Trendelenburg maneuver. However, this experiment was carried out on healthy hearts with normal coronary arteries, and such findings cannot be applied to diseased coronaries with ischemic myocardium.
Beside the exposure and stabilization techniques and the use of intracoronary shunt, anesthetic management appears as an essential part of the hemodynamics optimization strategy. Our anesthetic technique relies on two principles. Firstly, the heart rate should be slow and the myocardium contractility should be limited in order to offer the best conditions for the grafting. For these purposes, preoperative ß-blocker and intraoperative diltiazem were used. Secondly, the tools applied to maintain hemodynamics, when needed, should not increase myocardial oxygen consumption. Therefore, atrial pacing and noradrenaline were used, while ß-adrenergic inotropes were avoided.
The impact of other strategies of exposure and stabilization have been reported in previous clinical series [1517]. As expected, the use of the stabilization device as an exposure tool led to significant hemodynamical changes in all three territories [15,16]. The distinction between the exposure and the stabilization phase with the Bristol technique led to improved hemodynamics. However, significant changes were still noted with the posterior descending artery and the circumflex branches. Notably, with this technique, the arms of the swab were pulled across the heart during the exposure of these two territories, which could explain the observed changes. With our technique, the hemodynamical parameters were nearly unchanged for both the anterior and the posterior walls, while the lateral wall appeared to have the largest impact on hemodynamics albeit non significant. This trend is in keeping with the other studies which all reported the most severe disturbances associated with lateral wall exposure. The most striking difference with the other studies is the remarkable hemodynamical stability observed during posterior wall exposure which was similar to that of the anterior wall.
This study was designed to analyze a homogeneous group of patients and to obtain comparable data. Therefore, in contrast to others, only patients requiring three grafts, one to each side of the heart, were selected and the three walls were always revascularized in the same sequential order. Moreover, an ejection fraction
30% was required. With these criteria, the interferences of different sequences of grafting, different timings of grafting and severe ventricular dysfunction were avoided. Notably, a pre-established sequence of grafting may be safely followed independently of the degree of stenosis of the different coronary arteries only when intracoronary shunts are systematically used. We performed the LAD-LITA anastomosis last in order to allow enough time to the papaverine to diffuse to the LITA graft. Of course, this sequence should not be considered as a recommendation and the choice of the sequence is dictated by the surgeon's preference.
Bringing the heart back to its anatomical position between the grafts in order to allow hemodynamical recovery has been described by previous groups [16,17]. Nevertheless, with the present technique, good hemodynamics could be maintained despite the fact that no time was allowed for the heart to resume between the grafts. Such a maneuver appears unnecessary provided that the principles of the present technique are respected.
No proper echocardiographic window could be found once traction was applied to the arms of the swab. This is mainly due to the interposition of the swab between the heart and the echocardiographic probe, because filling the pericardium with saline did not improve the echocardiographic access. The monitoring was limited to hemodynamical measurements. Nevertheless, this drawback is compensated by the good hemodynamical tolerance to the heart manipulation.
The results of initial experimental [13,14] and clinical studies [16] have prompted the development of miniaturized circulatory assist system [1820] in order to stabilize the hemodynamical situation especially for the grafting of posterior and lateral walls. It is clear from the present results that with improved techniques of exposure and stabilization, such devices are not necessary for routine OPCAB. This is supported by the recent large series of OPCAB which did not use circulatory support system [911] even in a subgroup of patients with ejection fraction
30% [21]. Moreover, the aim of OBCAB is to reduce the invasiveness of the procedure. Performing OPCAB without circulatory support is in accordance with this philosophy, as the inflammatory response to foreign surfaces and the full dose of heparin with its subsequent clotting disturbances are avoided.
In conclusion, the present technique of exposure and stabilization which avoids compression of the heart chambers allows stable hemodynamics during OPCAB whichever the myocardial area is revascularized. This technique is simple, reproducible and applies the same principle to all the arterial segments.
4.1. Limitations
In order to maintain the homogeneity of the study group, patients with an ejection fraction
30% were selected. This study did not address the patients with a severe left ventricular dysfunction, and clearly further study is needed for this group. The right coronary artery was not specifically analyzed because the indication to bypass the right coronary artery was limited to critical proximal stenosis or occlusion, and in the present series, it occurred that all the patients were candidates for the revascularization of its branches. Cardiac output measurements were performed on heart with altered left and right ventricular geometry. Whether these conditions interfere with the validity of such measurements remains to be determined. Nevertheless, while absolute values of cardiac output may be questioned, their trend throughout the manipulations parallel those of the SvO2, which advocates for the validity of their profile.
| References |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
T. Omae, Y. Kakihana, A. Mastunaga, I. Tsuneyoshi, K. Kawasaki, Y. Kanmura, and R. Sakata Hemodynamic Changes During Off-Pump Coronary Artery Bypass Anastomosis in Patients with Coexisting Mitral Regurgitation: Improvement with Milrinone Anesth. Analg., July 1, 2005; 101(1): 2 - 8. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Verma, P. W.M. Fedak, R. D. Weisel, P. E. Szmitko, M. V. Badiwala, D. Bonneau, D. Latter, L. Errett, and Y. LeClerc Off-Pump Coronary Artery Bypass Surgery: Fundamentals for the Clinical Cardiologist Circulation, March 16, 2004; 109(10): 1206 - 1211. [Full Text] [PDF] |
||||
![]() |
P.-G. Chassot, P. van der Linden, M. Zaugg, X. M. Mueller, and D. R. Spahn Off-pump coronary artery bypass surgery: physiology and anaesthetic management{dagger} Br. J. Anaesth., March 1, 2004; 92(3): 400 - 413. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. L. Ngaage Off-pump coronary artery bypass grafting: the myth, the logic and the science Eur. J. Cardiothorac. Surg., October 1, 2003; 24(4): 557 - 570. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||