Eur J Cardiothorac Surg 2003;23:788-793
© 2003 Elsevier Science NL
a Department of Cardio-thoracic Surgery, University of Vienna, Leitstelle 20, Waehringer Guertel 18-20, 1090 Vienna, Austria
b Department of Interventional Radiology and Angiography, University of Vienna, Waehringer Guertel 18-20, 1090 Vienna, Austria
Received 5 September 2002; received in revised form 15 January 2003; accepted 22 January 2003.
* Corresponding author. Tel.: +43-1-40400-5620, fax: +43-1-40400-5640
e-mail: martin.grabenwoeger{at}univie.ac.at
| Abstract |
|---|
|
|
|---|
Key Words: Endovascular stent graft Acute dissection type B Traumatic aortic aneurysm Penetrating ulcer
| 1. Introduction |
|---|
|
|
|---|
Penetrating aortic ulcers result from progressive erosion of atheromatous plaques perforating the internal elastic lamina. Penetrating ulcers are considered a predisposing condition for aortic dissection and spontaneous rupture. As penetrating ulcers are associated with comorbidities like hypertension, peripheral or coronary artery disease and chronic renal insufficiency, patients are often not eligible for conventional surgical repair [10]. In the case of traumatic aortic dissections, the patients often present with multiple injuries and therefore open repair is a high risk procedure because of bad overall condition or the need of systemic heparinization [11].
In the present study, we evaluate the feasibility and safety of ESG placement in patients with acute aortic syndromes, such as acute dissection type B, penetrating ulcers and traumatic aneurysms.
| 2. Patients and methods |
|---|
|
|
|---|
There were three female (15.8%) and 16 male (84.2%) patients with a mean age of 61 years (2085 years). Time interval between diagnosis and stent grafting ranged from 4 h to 6 days (mean 2 days). At the time of operation, one patient was hemodynamically unstable, the remaining patients were treated under stable conditions.
Significant comorbidities were hypertension in 17 patients (89.4%), coronary artery disease with previous myocardial infarction in three patients (15.8%), chronic renal failure in three patients (15.5%) and COPD in eight patients (42.1%). Three patients had previous cardiac surgery, two CABG and one aortic valve replacement.
Symptoms present at the time of intervention were chest or back pain in all patients, dyspnea in two patients, low output syndrome in one patient and three patients with a penetrating ulcer exhibiting hemoptysis.
The zone of the primary entry tear was localized in the proximal descending aorta in 11 patients, in the isthmic zone in the two patients presenting traumatic dissection and in the mid-portion of the thoracic aorta in the remaining six patients. Procedural success was defined by complete sealing of the primary entry tear followed by obliteration of the false lumen at least in the thoracic region. In the case of penetrating ulcer and localized traumatic dissection, complete coverage of the injured aortic segment was defined as procedural success.
2.1. Endovascular procedure
All endovascular procedures were performed in an angio-suite by a team of cardiovascular surgeons and interventional radiologists. Sixteen patients were operated in general anesthesia, three patients were treated in spinal anesthesia. For vascular access the femoral artery was surgically exposed in 13 patients (68.4%), the iliac artery was used in six patients (31.6%). A six French pig-tail catheter was advanced over the left brachial artery into the ascending aorta to allow intraprocedural angiography. An angiography with an automatic injector was performed to localize precisely the primary entry site in patients with acute type B dissection or traumatic dissection or the site of contained aortic perforation. Thereafter, a pig-tail catheter was introduced from the femoral or iliac artery into the ascending aorta. The catheter was advanced under angiographic control in a stepwise manner to confirm introduction into the true lumen. Over the pig-tail catheter an extra-stiff guidewire (Backup Meier, Boston Scientific, Natick, MA) was placed into the ascending aorta.
Prior to stent graft insertion, 5000 IU of heparin sodium was administered intravenously and antibacterial medication was given routinely. Next, the delivery system was introduced through the true lumen and was carefully advanced into the optimal position under fluoroscopic guidance. After correct positioning of the device, the stent graft was deployed.
Finally, an angiogram was performed to confirm the position of the device relative to the entry tear of perforation site, to evaluate patency of the left subclavian artery and blood flow in the visceral arteries and to verify the effectiveness of the stent grafting. Thereafter the placement system was removed and the arteriotomy was closed in the conventional manner.
Patients were subjected to a strict follow-up protocol that requires a contrast spiral computed tomography (CT) scan and clinical evaluation at 3.6 and 12 months after surgery and then annually thereafter.
2.2. Stent graft systems
Two different stent graft systems are available to our department. The GORE Thoracic Excluder Endoprothesis (W.L. Gore and Associates, Sunnyvale, CA) was used in 15 patients (79%). Exclusion of thoracic aortic aneurysms with the TALENT endoluminal stent graft system (Medtronic, Sunrise, FL) was performed in 4 patients (21%).
The TALENT stent graft consists of a nitinol wire stent shaped in a zigzag formation, which is covered with extra-thin polyester (Dacron). A straight nitinol wire severs the length of the device and avoids twisting or kinking. This self-expandable stent graft is compressed over a placement catheter. Both the stent graft and the catheter are loaded into a polyurethane sheath for insertion. The endoluminal stent graft system is passed over the guidewire and positioned at the desired location as determined by intraoperative angiography. After exact positioning, the stent graft released by removing the sheath.
The GORE Thoracic Excluder stents are constructed differently. The system is placed into the vasculature through an introduction sheath. The stent graft itself is mounted on a placement catheter. Development of the stent graft is achieved by pulling on a string at the end of the placement catheter. GORE stent grafts are available in standard sizes.
| 3. Results |
|---|
|
|
|---|
One or two stent grafts per patient were necessary to cover the aortic lesion (mean 1.4 stents/patient). Patients with penetrating ulcers were treated with one stent graft. In the case of type B dissection and traumatic lesions, most of the patients received two stent grafts. The goal of the intervention was not only to cover the primary entry tear, but also to reinforce the dissected aorta. Stent diameters ranged from 26 to 40 mm (mean 35.7 mm) and length varied from 50 to 200 mm (mean 100 mm).
CT scans performed at the time of discharge revealed complete sealing of the aorta at the perforating site or local dissection area in patients with penetrating ulcer or traumatic lesions. Patients treated for acute type B dissection showed closure of the primary entry tear with thrombosis of the false lumen at the height of the stent graft in all patients. Therefore, procedural success was 100%. Complete obliteration of the false lumen could be achieved in 2 patients, whereas the remaining patients exhibit perfusion of the false lumen in the abdominal region via re-entries at the height of the renal arteries.
In the postoperative period, two complications were encountered. One patient treated for acute type B dissection developed incomplete paraplegia within 14 h postoperatively. Cerebrospinal fluid drainage was installed 8 h after onset of symptoms by inserting a lumbar catheter in the height of L3L4. Initial cerebrospinal fluid pressure was 45 mmHg. To reach the target pressure of 15 mmHg, liquor was drained for 96 h. A total volume of 800 ml was collected and neurologic symptoms decreased continuously. After an uneventful postoperative course, the patient could be discharged with no remaining neurologic deficit. Another patient with type B dissection developed ischemia of the left arm after overstenting of the left subclavian artery. Fourteen days after stent graft placement, subclavian to carotid artery transposition was performed.
Follow-up period ranged from 3 to 63 months (mean 17.2 months) and was 100% complete. Within the follow-up period, one patient treated for penetrating ulcer died due to myocardial infarction (late mortality 5.3%). Another patient was admitted at the emergency room 4 years after stenting due to a penetrating ulcer showing a contained rupture of the severely calcified aorta. CT scans revealed marked dilatation of the thoraco-abdominal aorta and a proximal type I endoleak resulting in a contained aortic rupture. Due to the morphology of the adjacent thoracic aorta, placement of additional stent grafts was not feasible. Therefore, open surgery with replacement of the thoraco-abdominal aorta using the left heart bypass technique had to be performed. After surgery, the patient recovered uneventfully. The remaining patients are doing fine and the completion of CT scans showed complete thrombosis of the false lumen of the entire aorta in two additional patients with type B dissections. The mean diameter of the false lumen of the dissected aorta decreased from 2.3±58 to 0.7±0.44 cm, and the true lumen increased from 1.56±0.5 to 4.10±0.60 cm in the thoracic region.
| 4. Comment |
|---|
|
|
|---|
|
In our series, two patients with acute traumatic aortic aneurysms were treated successfully with ESG (Fig. 2A, B ). One of these patients exhibited multiple bone fractures and injuries of liver and spleen. Thus, the patient was not a suitable candidate for total heparinization as required for conventional surgical repair. The traumatic rupture was located just at the offspring of the left subclavian artery. Overstenting of the subclavian artery was performed leading to a pulse deficit of the left arm without clinical symptoms. Based on this initial experience, placement of ESG is suggested to be an excellent treatment modality especially for the polytrauma patient, a high-risk candidate for conventional surgical repair.
|
|
|
|
In one patient, left subclavian-to-carotid artery bypass had to be performed, because of intermittent claudication of the left upper extremity caused by closure of the origin of the left subclavian artery. In the acute setting in contrast to elective cases it is our policy to overstent the left subclavian artery if necessary. Close monitoring of left upper extremity perfusion is performed. If ischemia develops staged revascularization procedures can be performed.
We therefore conclude that this technique can be considered as a valid treatment option in the emergency setting, especially when standard surgical procedures cannot be carried out due to severe comorbidities. However, close follow-up examination is indicated and long-term results have to be awaited to evaluate the real effectiveness of this method.
| Footnotes |
|---|
| Appendix A. Conference discussion |
|---|
|
|
|---|
Dr Grabenwoeger: In our opinion, we stent all patients, the complicated and the uncomplicated, the so-called uncomplicated type B dissection. But there are a lot of papers in the literature with a lot of patients that develop a chronic type B dissection and several years later you have to operate on them because of a diameter of 6 or 7 cm. So in our group there are some patients with signs of contained rupture and with a hematothorax, patients with malperfusion of one kidney, but also patients which had a diagnosed acute type B dissection, they had pain, but now they are stable patients. But we also stent the stable patients, not only the complicated cases.
Dr A. Haverich (Hannover, Germany): I only have one question, and that is regarding retrograde type A dissection in those patients where you did deploy the descending stent. Because I'm aware now of all unpublished data of 5 patients in Germany that suffered acute type A dissection either immediately at the time of deployment of the descending stent or even like 2 or 4 weeks after that event. The mortality in that situation is 80%, as far as I know. Have you experienced that, and how do you think we could avoid that complication?
Dr Grabenwoeger: Fortunately, we've never experienced this. I have heard a lot from colleagues that they had this problem. Maybe it is also a problem from the stent graft used. If you use the Talent stent graft system, there are stents available with so-called bare springs. These are metal bare springs, they are not covered by a tissue, by a Dacron. And I don't know if you are using this stent graft with this special patient, but in my opinion if you use, for example, a Talent stent graft system with bare springs, then you can, after stent deployment, you can induce with the bare springs in the aortic valve a second lesion and the retrograde type A dissection.
And also in type B dissection, we never expand with the balloon the stent. We only expand the stent, but we don't use the balloon for further expansion of the stent graft, too, because we don't want to put too much force on the dissected, on the fresh diseased aortic wall.
Dr H. Ogino (Osaka, Japan): I think the patients have some risk that might be very small of the spinal cord injury after stent graft. And in type B dissection the patient is quite stable. So in the type A dissection, the risk of the patient is a big aim. So how do you prevent the spinal cord injury?
Dr Grabenwoeger: Normally we put the stent graft only in the first third of the descending aorta, because just normally the primary entry tear is in the proximal area of the descending aorta. In the future, if you have a patient which has an uncomplicated type B dissection and he has his entry in the mid portion or distal portion of the descending artery, maybe I refuse to stent this patient because of obliteration of the important distal intercostals. Or you can also say, okay, we install prior to stenting a CSF drainage and afterwards. But I think if we have an uncomplicated type B dissection in the distal area, I would refuse.
Dr T. Carrel (Bern, Switzerland): Did you have strong evidence that you were able at least in one patient to reverse acute malperfusion of the visceral arteries with stenting?
Dr Grabenwoeger: A lot of patients, if you look perioperatively at the CT scans, you see at least a less perfused kidney. We saw 3 or 4 patients that one kidney was not perfused or less perfused. And after stent graft placement, you see really an increase in the perfusion of the kidney, which was not perfused or less perfused before. There was no patient in the series with a real visceral malperfusion or with a cold leg. But only from the point of the kidneys, I could say that we have good results.
| References |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
H. Girn, S McPherson, T Nicholson, A. Mavor, S Homer-Vanniasinkam, and M. Gough Short series of emergency stent-graft repair of symptomatic penetrating thoracic aortic ulcers (PTAU) Vascular Medicine, May 1, 2009; 14(2): 123 - 128. [Abstract] [PDF] |
||||
![]() |
A. Kaya, R. H. Heijmen, H. Rousseau, C. A. Nienaber, M. Ehrlich, P. Amabile, J.-P. Beregi, and R. Fattori Emergency treatment of the thoracic aorta: results in 113 consecutive acute patients (the Talent Thoracic Retrospective Registry) Eur. J. Cardiothorac. Surg., February 1, 2009; 35(2): 276 - 281. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Zimpfer, H. Schima, M. Czerny, M.-T. Kasimir, S. Sandner, G. Seebacher, U. Losert, P. Simon, M. Grimm, E. Wolner, et al. Experimental Stent-Graft Treatment of Ascending Aortic Dissection Ann. Thorac. Surg., February 1, 2008; 85(2): 470 - 473. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Buz, B. Zipfel, S. Mulahasanovic, M. Pasic, Y. Weng, and R. Hetzer Conventional surgical repair and endovascular treatment of acute traumatic aortic rupture Eur. J. Cardiothorac. Surg., February 1, 2008; 33(2): 143 - 149. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. G. Svensson, N. T. Kouchoukos, D. C. Miller, J. E. Bavaria, J. S. Coselli, M. A. Curi, H. Eggebrecht, J. A. Elefteriades, R. Erbel, T. G. Gleason, et al. Expert Consensus Document on the Treatment of Descending Thoracic Aortic Disease Using Endovascular Stent-Grafts Ann. Thorac. Surg., January 1, 2008; 85(1_Supplement): S1 - S41. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Gorlitzer, W. Wislocki, J. Meinhart, and M. Grabenwoger Treatment of chronic aortic type A dissection with a new designed hybridprosthesis Eur. J. Cardiothorac. Surg., February 1, 2007; 31(2): 315 - 317. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. M. Sundt Intramural Hematoma and Penetrating Atherosclerotic Ulcer of the Aorta Ann. Thorac. Surg., February 1, 2007; 83(2): S835 - S841. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Yang, J. Zuo, L. Yang, W. Duan, L. Xiong, M. Zheng, H. Cui, and D. Yi Endovascular stent-graft treatment of thoracic aortic dissection Interactive CardioVascular and Thoracic Surgery, December 1, 2006; 5(6): 688 - 691. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. Ferrari, P. Tozzi, and L. von Segesser Thoracic aorta emergencies: is the endovascular treatment the new gold standard? Interactive CardioVascular and Thoracic Surgery, December 1, 2006; 5(6): 730 - 734. [Abstract] [Full Text] [PDF] |
||||
![]() |
M R Jones and J H Reid Emergency chest radiology: thoracic aortic disease and pulmonary embolism Imaging, September 1, 2006; 18(3): 122 - 138. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Kaya, R. H. Heijmen, T. Th. Overtoom, J.-A. Vos, W. J. Morshuis, and M. A. Schepens Thoracic Stent Grafting for Acute Aortic Pathology Ann. Thorac. Surg., August 1, 2006; 82(2): 560 - 565. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Zimpfer, M. Czerny, J. Kettenbach, M. Schoder, E. Wolner, J. Lammer, and M. Grimm Treatment of Acute Type A Dissection by Percutaneous Endovascular Stent-Graft Placement Ann. Thorac. Surg., August 1, 2006; 82(2): 747 - 749. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Fattori, C. A. Nienaber, H. Rousseau, J.-P. Beregi, R. Heijmen, M. Grabenwoger, P. Piquet, L. Lovato, C. Dabbech, S. Kische, et al. Results of endovascular repair of the thoracic aorta with the Talent Thoracic stent graft: The Talent Thoracic Retrospective Registry. J. Thorac. Cardiovasc. Surg., August 1, 2006; 132(2): 332 - 339. [Abstract] [Full Text] [PDF] |
||||
![]() |
F Ahmad, N Cheshire, and M Hamady Acute aortic syndrome: pathology and therapeutic strategies. Postgrad. Med. J., May 1, 2006; 82(967): 305 - 312. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Eggebrecht, C. A. Nienaber, M. Neuhauser, D. Baumgart, S. Kische, A. Schmermund, U. Herold, T. C. Rehders, H. G. Jakob, and R. Erbel Endovascular stent-graft placement in aortic dissection: a meta-analysis Eur. Heart J., February 2, 2006; 27(4): 489 - 498. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. R. Lebl, R. A. Dicker, D. A. Spain, and S. I. Brundage Dramatic shift in the primary management of traumatic thoracic aortic rupture. Arch Surg, February 1, 2006; 141(2): 177 - 180. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Dong Xu, Z. Zhong Li, F. J. Huang, J. F. Yang, X. Y. Wang, Z. G. Zhang, J. Hui Du, and Y. Q. Sun Treating Aortic Dissection and Penetrating Aortic Ulcer with Stent Graft: Thirty Cases Ann. Thorac. Surg., September 1, 2005; 80(3): 864 - 868. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Czerny, D. Zimpfer, T. Fleck, R. Gottardi, M. Cejna, M. Schoder, J. Lammer, E. Wolner, M. Grabenwoger, and M.-R. Mueller Successful Treatment of an Aortoesophageal Fistula After Emergency Endovascular Thoracic Aortic Stent-Graft Placement Ann. Thorac. Surg., September 1, 2005; 80(3): 1117 - 1120. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Morishita, Y. Kurimoto, N. Kawaharada, J. Fukada, Y. Hachiro, Y. Fujisawa, and T. Abe Descending Thoracic Aortic Rupture: Role of Endovascular Stent-Grafting Ann. Thorac. Surg., November 1, 2004; 78(5): 1630 - 1634. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Grabenwoger, T. Fleck, M. Ehrlich, M. Czerny, D. Hutschala, M. Schoder, J. Lammer, and E. Wolner Secondary surgical interventions after endovascular stent-grafting of the thoracic aorta Eur. J. Cardiothorac. Surg., September 1, 2004; 26(3): 608 - 613. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. K. von Segesser, B. Marty, P. Tozzi, C. Huber, I. Bruschweiler, A. Gallino, D. Hayoz, and P. Ruchat Endovascular surgery for failed open aortic aneurysm repair Eur. J. Cardiothorac. Surg., September 1, 2004; 26(3): 614 - 620. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Melnitchouk, T. Pfammatter, A. Kadner, H. Dave, H. Witzke, O. Trentz, M. Turina, and M. Lachat Emergency stent-graft placement for hemorrhage control in acute thoracic aortic rupture Eur. J. Cardiothorac. Surg., June 1, 2004; 25(6): 1032 - 1038. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Ihnken, D. Sze, M. D. Dake, D. Fleischmann, P. Van Der Starre, and R. Robbins Successful treatment of a Stanford type A dissection by percutaneous placement of a covered stent graft in the ascending aorta J. Thorac. Cardiovasc. Surg., June 1, 2004; 127(6): 1808 - 1810. [Full Text] [PDF] |
||||
![]() |
K. R. Cho, A. W. Stanson, D. D. Potter, K. J. Cherry, H. V. Schaff, and T. M. Sundt III Penetrating atherosclerotic ulcer of the descending thoracic aorta and arch J. Thorac. Cardiovasc. Surg., May 1, 2004; 127(5): 1393 - 1401. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |