Eur J Cardiothorac Surg 2004;25:985-992
© 2004 Elsevier Science NL
a Faculty of Medicine, Institute of Cancer Research and Molecular Medicine, Norwegian University of Science and Technology, N-7489 Trondheim, Norway
b Department of Clinical Chemistry, Ulleval University Hospital, N-0407 Oslo, Norway
c St Elisabeth Heart Center, Trondheim University Hospital, N-7018 Trondheim, Norway
Received 23 October 2003; received in revised form 23 February 2004; accepted 2 March 2004.
* Corresponding author. Department of Clinical Chemistry, FUS, 1-K, Ulleval University Hospital, N-0407 Oslo, Norway. Tel.: +47-2301-5034; fax: +47-2211-8479
e-mail: brit.dybdahl{at}ulleval.no
| Abstract |
|---|
|
|
|---|
Key Words: Cell-signaling proteins Coronary artery bypass surgery Heat-shock proteins Immunology Ischemia/reperfusion Off-pump
Abbreviations: ACC, aortic cross-clamp CABG, coronary artery bypass grafting CD, cluster of differentiation molecule CK-MB, creatine kinase-MB CPB, cardiopulmonary bypass CRP, C-reactive protein cTnT, cardiac Troponin T ECG, electrocardiogram ELISA, enzyme-linked immunosorbent assay HSP, heat-shock protein ICU, intensive care unit IL, interleukin IRAK, IL-1R-associated kinase LVEF, left ventricular ejection fraction MyD88, myeloid differentiation factor 88 NF-
B, nuclear factor-kappa B NO, nitric oxide NSAID, non-steroidal anti-inflammatory drug OPCAB, off-pump coronary artery bypass grafting PRBC, packed red blood cells Th, T helper cell TLR, toll-like receptor TNF
, tumor necrosis factor-alpha
| 1. Introduction |
|---|
|
|
|---|
Heat-shock proteins (HSPs) are abundant, soluble, intracellular proteins, normally present neither in blood nor other body fluids [9]. HSPs may be induced under stressful conditions like ischemia-reperfusion, and may then be released into the circulation from necrotic or stressed viable cells. The primary intracellular function of HSPs is as molecular chaperones, counteracting the unfolding, misfolding and pathological modification of critical proteins in e.g. ischemic injury [10].
Extracellular HSPs are suggested as danger signals that lead to the activation of innate and adaptive proinflammatory responses [9]. In vitro, it has previously been shown that monocytes stimulated with the inducible HSP70 release proinflammatory cytokines such as interleukin (IL)-6 and tumor necrosis factor (TNF)
[11,12]; and the HSP70-induced signaling may be mediated through the MyD88/IRAK/NF-
B signal transduction pathway [13]. Both Toll-like receptor (TLR)-2 and TLR-4 together with CD14 have been suggested to be involved in this signal transduction [11,13].
We have previously shown that the stress-inducible HSP70 (also identified as HSP72) is rapidly released into the circulation following CABG [11]. Furthermore, HSP70 has been detected in atrial biopsies from patients undergoing CABG [14]. We were curious to find a possible difference in the inflammatory response, represented by the release of HSP70, following OPCAB compared to CABG. Considering ischemia induces HSP70, we hypothesized that use of cardiac arrest and CPB leads to increased release of HSP70. Accordingly, the first aim of the present study was to compare HSP70 release, inflammatory response, and markers of myocardial damage in CABG and OPCAB. Secondly, we wanted to explore the kinetics of HSP70 release during and after open heart surgery. The third aim was to evaluate the myocardial contribution to circulating HSP70.
| 2. Patients and methods |
|---|
|
|
|---|
2.1. Patients
From January to August 2002, 20 consecutive patients referred for elective CABG or OPCAB at the St Elisabeth Heart Center, Trondheim, Norway, were recruited to this prospective study. Ten patients underwent CABG, and 10 underwent OPCAB. The patients had angiographically verified coronary artery disease, were <75 years old and had no signs of infection preoperatively. Patients undergoing reoperations, combined procedures or emergency surgery were not included. The regional ethics committee approved the study, and informed written consent was obtained from each patient.
2.2. Anesthesia and surgical procedure
All patients underwent a procedure with median sternotomy. Anesthesia was induced with diazepam, fentanyl, thiopental, and pancuronium and maintained with isoflurane, fentanyl and nitrous oxide. Cephalothin was used as perioperative antibiotic prophylaxis. An initial dose of 300 IU/kg heparin was given to all patients, and additional heparin was given when necessary to maintain clotting time >480 s during CABG and >350 s during OPCAB. Finally, heparin was neutralized with protamine sulfate. The patients undergoing CABG were cooled down to 34 °C; we used St Thomas cardioplegic solution No. I [15], or cold blood cardioplegia. CPB was performed with non-pulsatile flow of 2.4 l/min per m2 body surface area with a roller pump. A membrane oxygenator with synthetic, biocompatible surfaces (Maxima, Medtronic) was used in all CABG operations. The pump prime consisted of 1800 ml Ringer's solution and 7500 IU heparin. The Medtronic Octopus System (Medtronic Inc.) was used to expose and stabilize the target coronary artery during off-pump procedures. All the patients received a trans-atrial retrograde cardioplegia catheter (Edwards Lifesciences Corp.) in the coronary sinus at the beginning of the procedure, which was withdrawn before closure. Correct positioning of the catheter with the tip at the level of the posterior interventricular vein was assessed by palpation of the cannula and transesophageal echocardiography. Furthermore, blood was withdrawn slowly to avoid aspiration of right atrial blood.
2.3. Blood sampling
Blood samples were taken through an indwelling radial artery catheter before induction of anesthesia, before starting CPB (or the corresponding time point for off-pump operations), at the end of CPB (immediately following injection of protamine sulfate), 2 and 6 h thereafter and at 8.00 a.m. the next day. Peroperatively, blood was also collected from the coronary sinus through the retrograde cardioplegia catheter. Plasma samples were centrifuged immediately after collection, whereas serum samples were centrifuged following 30 min on the bench. Both serum and plasma were aliquoted and frozen in several vials at 80 °C until analyzed.
2.4. Serum and plasma analyses
Serum HSP70 was measured with StressXpress Hsp70 ELISA Kit, sensitivity 200 pg/ml (Stressgen Biotechnologies Corp). IL-6 and IL-8 in serum were measured with Quantikine Human Immunoassays (R&D Systems Inc), sensitivities 0.70 and 10 pg/ml, respectively. Serum IL-10 was analyzed with Biosource IL-10 EASIA Kit (Biosource Europe SA), sensitivity 1 pg/ml. Cardiac Troponin T (cTnT) and creatine kinase-muscle brain isoenzyme (CK-MB) were measured by the Department of Clinical Chemistry, Trondheim University Hospital, on an Elecsys 2010 Analyser (Roche), detection limits 0.010 and 0.10 µg/l, respectively. Serum-free hemoglobin was analyzed by means of a photometrical method in the same laboratory. We used the hospital routine analyses for quantification of C-reactive protein (CRP; detection limit 5 mg/l), whole blood hemoglobin concentration, leukocyte and platelet counts.
2.5. Statistical analyses
Because of non-Gaussian distribution of most data, we used non-parametric tests and median values with quartiles in the presentation. Comparisons within groups over time were made by means of the Friedman test and Dunn's multiple comparison test. To compare groups, the MannWhitney test was used. We performed Wilcoxon signed ranks test to compare blood samples collected from the coronary sinus and the arterial line at the same time point. Differences were considered statistically significant at the level of P<0.05. For correlation analyses, we used Spearman's rho.
| 3. Results |
|---|
|
|
|---|
|
|
|
|
|
|
|
|
| 4. Discussion |
|---|
|
|
|---|
Several studies have shown that ischemia-reperfusion induces HSP70 in myocardial cells [14,16]. In this study, the HSP70 concentration in blood from the coronary sinus did not differ significantly from HSP70 in peripheral arterial blood. We cannot exclude the possibility of a minor contamination by right atrial blood in coronary sinus samples, which might mask eventual differences in HSP70 concentration between the systemic and the coronary circulation. It appears more likely, however, that most of the HSP70 induced in the heart is not released into the systemic circulation, but stays localized in the heart.
Blood cells are another putative source of circulating HSP70 following CABG. HSP70 has previously been detected in monocytes and granulocytes in humans [17], and in immature red cells of chicken embryos [18]. Physical damage of the cells circulating through the heartlung machine may lead to induction and release of HSP70. The correlation between serum free Hb and HSP70 in CABG patients led us to examine the HSP70 content of erythrocytes from healthy people. The HSP70 content of in vitro lysed erythrocytes diluted in autologous serum was very low (data not shown). As such, erythrocytes appear not to be an important source of HSP70. However, the degree of ex vivo hemolysis in CABG patients may indicate the degree of leukocyte damage; monocytes and granulocytes may be substantial contributors to circulating HSP70 in CABG patients.
Our OPCAB patients had a small but significant increase in serum HSP70. This could be due to the surgical trauma, or the local ischemia caused by the clamping of coronary arteries. In addition, manipulation and stretching of the heart during the surgery may cause increase of HSP70 in the heart. It has been shown in rabbit hearts, that stretch or reduced shortening may lead to induction of HSP70 mRNA [19]. This mechanism may also affect CABG patients, perhaps even more than OPCAB patients; aortic cross-clamping may cause such stretch [19], and we found a strong correlation between ACC time and HSP70 concentration. A long ACC time may indicate more myocardial stretch and more ischemia. Thus, it is tempting to suggest that the heart contributes to the circulating HSP70. The length of ACC, however, also indicates the complexity of the operation, and as such the strength of the stimulus for HSP70 release, whatever the source. On the other hand, patients operated with CPB had more circulating cTnT and CK-MB postoperatively than patients operated off-pump, as shown by others [20]. We detected a correlation between the HSP70 concentration and both cTnT and CK-MB, and the possibility that HSP70 may be an additional marker of myocardial damage cannot be excluded.
Randomization of this study was not carried out. The patients were selected for CABG or OPCAB according to the hospital treatment policy at the time; in routine cases 3-vessel diseased patients were scheduled for standard CABG, and patients with 1 to 2-vessel disease were treated according to an OPCAB protocol. As such, the CABG patients had more distal anastomoses than the OPCAB patients. In addition, the heparin dosages were slightly higher in CABG patients (data not shown). Although we cannot exclude an effect of heparin upon the Hsp70 measurements, the small dosage difference may, most likely, be of minor importance. There was no difference in total operation time between the groups. In our view, the main difference between the patients during surgery apparently was the use of cardiac arrest and CPB in CABG patients, but not in OPCAB patients. Thus, although the lack of randomization is a formal weakness of the study, we suggest that this has negligible influence on the main issue of this investigation.
The systemic inflammatory response in the study patients was evidenced by the increase of interleukins and CRP. Serum IL-6 did not differ significantly between the two groups, but there was a trend of IL-6 being higher in OPCAB patients on day 1 postoperatively. The similarity in IL-6 increases between CABG and OPCAB patients has been described previously [2,21]. IL-6 is possibly more related to the surgical trauma than to ischemia. Furthermore, the IL-6 concentration was higher in the coronary sinus than in peripheral blood, supporting previous reports that suggest the myocardium as an important source of IL-6 [22]. We did not detect statistically significant differences in serum IL-8 between the groups, although others have found higher IL-8 concentrations in patients undergoing procedures with CPB [21].
There was a remarkable difference in IL-10 between the groups. This anti-inflammatory cytokine was evident at the end of surgery in 7 of 10 CABG patients, but in no OPCAB patients. Similar results have been described previously [21]. Most studies show that IL-10 suppresses pro-inflammatory cytokines, and serum IL-10 may indicate the magnitude of inflammatory stress. Why patients with release of IL-10 have the highest HSP70 concentrations is, as yet, unknown. Whereas extracellular HSP72 has been shown to induce IL-6, TNF-
and IL-12 in monocytes, IL-10 has not been found in supernatants of monocytes stimulated with HSP72 [23]. It has been suggested, however, that HSP70 induces Th2 type CD4+ T cells, producing IL-10 among others [24]. As such, HSP70 may be part of an immunoregulatory response that has the potential to control proinflammatory responses [24].
There is increasing evidence for activation of the immune system by extracellular HSP70 [9,1113,23,24]. Recently, however, questions have been asked regarding the mechanism by which Hsp70 activates innate immunity. Endotoxin contamination of recombinant human Hsp70 preparations has been a problem in previous in vitro studies [25]. Thus, further research both in vitro, and in larger clinical studies is needed in order to understand the clinical implications of Hsp70 release following e.g. heart surgery.
To summarize the present study, we have shown that significantly more HSP70 is released after CABG than after OPCAB, possibly indicating a difference in inflammatory responses, cellular stress or damage, between these two procedures. Furthermore, the release of HSP70 appears rapidly, with peak HSP70 concentration at 2 h postoperatively. Both leukocytes and the heart may contribute to the circulating Hsp70 following open heart surgery. The role of extracellular HSP70 as an immunoregulatory agent may be of importance in the host defence postoperatively.
| Acknowledgments |
|---|
| References |
|---|
|
|
|---|
release by murine macrophages. J Biol Chem 2003;278:174-179.This article has been cited by other articles:
![]() |
N. Zou, L. Ao, J. C. Cleveland Jr., X. Yang, X. Su, G.-Y. Cai, A. Banerjee, D. A. Fullerton, and X. Meng Critical role of extracellular heat shock cognate protein 70 in the myocardial inflammatory response and cardiac dysfunction after global ischemia-reperfusion Am J Physiol Heart Circ Physiol, June 1, 2008; 294(6): H2805 - H2813. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. R. Untch, W. P. Jeske, J. Schwartz, S. Botkin, M. Prechel, J. M. Walenga, and M. Bakhos Inflammatory and Hemostatic Activation in Patients Undergoing Off-Pump Coronary Artery Bypass Grafting Clinical and Applied Thrombosis/Hemostasis, April 1, 2008; 14(2): 141 - 148. [Abstract] [PDF] |
||||
![]() |
T. Szerafin, K. Hoetzenecker, S. Hacker, A. Horvath, A. Pollreisz, P. Arpad, A. Mangold, T. Wliszczak, M. Dworschak, R. Seitelberger, et al. Heat Shock Proteins 27, 60, 70, 90{alpha}, and 20S Proteasome in On-Pump Versus Off-Pump Coronary Artery Bypass Graft Patients Ann. Thorac. Surg., January 1, 2008; 85(1): 80 - 87. [Abstract] [Full Text] [PDF] |
||||
![]() |
V. Falk and F. W. Mohr Minimally Invasive Myocardial Revascularization Card. Surg. Adult, January 1, 2008; 3(2008): 697 - 710. [Full Text] |
||||
![]() |
M. A. Chase, D. S. Wheeler, K. M. Lierl, V. S. Hughes, H. R. Wong, and K. Page Hsp72 Induces Inflammation and Regulates Cytokine Production in Airway Epithelium through a TLR4- and NF-{kappa}B-Dependent Mechanism J. Immunol., November 1, 2007; 179(9): 6318 - 6324. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. H. Rosner and M. D. Okusa Acute Kidney Injury Associated with Cardiac Surgery Clin. J. Am. Soc. Nephrol., January 1, 2006; 1(1): 19 - 32. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Lund, K. Sundet, B. Tennoe, P. K. Hol, K. A. Rein, E. Fosse, and D. Russell Cerebral Ischemic Injury and Cognitive Impairment After Off-Pump and On-Pump Coronary Artery Bypass Grafting Surgery Ann. Thorac. Surg., December 1, 2005; 80(6): 2126 - 2131. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. J. Rastan, H. B. Bittner, J. F. Gummert, T. Walther, C. V. Schewick, E. Girdauskas, and F. W. Mohr On-pump beating heart versus off-pump coronary artery bypass surgery--evidence of pump-induced myocardial injury Eur. J. Cardiothorac. Surg., June 1, 2005; 27(6): 1057 - 1064. [Abstract] [Full Text] [PDF] |
||||
![]() |
B Dybdahl, S A Slordahl, A Waage, P Kierulf, T Espevik, and A Sundan Myocardial ischaemia and the inflammatory response: release of heat shock protein 70 after myocardial infarction Heart, March 1, 2005; 91(3): 299 - 304. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |