| Abstract |
|---|
|
|
|---|
Key Words: Congenital heart disease Pulmonary valve Tetralogy of Fallot Heart valve Mechanical Reoperation
| 1. Introduction |
|---|
|
|
|---|
Most surgeons replace the pulmonary valve with an allograft [3], although xenografts are also employed [4,2]. However, these valvar substitutes both deteriorate over time, making (potentially multiple) reoperations necessary, each associated with morbidity and mortality [57]. Additionally, patients usually do not relish the prospect of multiple re-operations. Replacement with a mechanical valvar prostheses most likely reduces the number of reoperations but has a less favourable reputation, despite a paucity of papers on results, let alone sizable series of patients (Table 1 ) [815].
|
| 2. Materials and methods |
|---|
|
|
|---|
|
|
2.2 Follow-up
No patients were lost to follow-up, and all were seen on a regular basis by a cardiologist specialised in congenital heart disease. Follow-up time ranged from 2 months to 18 years (mean 5.5 years). Special attention was paid to RV function and prosthetic valvar performance by transthoracic and/or transesophageal echocardiography.
2.3 Statistics
Seventy percent of confidence limits were calculated where applicable (70% CL).
| 3. Results |
|---|
|
|
|---|
RV dilatation (due to pulmonary insufficiency) was present in 20 cases and improved in 15 patients; in 2 patients RV dimensions remained the same; one patient died postoperatively; in 2 patients follow-up was to short to judge. No postoperative pulmonary regurgitation was found, apart from minor early diastolic intravalvar regurgitation, considered to be normal for valvar prostheses. All surviving patients (25) perform well (17 patients are NYHA class I, 8 patients are NYHA class II) and improved in exercise tolerance after the operation. All surviving patients are on coumadine medication and are advised to maintain an INR of 2.54.
| 4. Discussion |
|---|
|
|
|---|
Why mechanical pulmonary valvar replacement has such an unfavourable reputation is somewhat of a mystery. Series of any substantial size and follow-up are lacking. Nonetheless the number of grown-up congenital heart disease (GUCH) patients is increasing to significant numbers. As we know now a large number of patients with corrected Tetralogy of Fallot is at risk of failure of their right ventricle [16], mostly because of pulmonary regurgitation (PR) induced by a transannular patch [1]. Particularly, in the long term, PR leads to diminished exercise capacity and rhythm disturbances, due to RV dilatation and dysfunction. This condition can be treated easily by surgical introduction of a competent valvar prosthesis in the pulmonary position.
The Guidelines for the Management of Patients with Valvular Heart Disease [3] by the American College of Cardiology and the American Heart Association do not recommend any particular surgical technique but state that pulmonary valve replacement is usually performed with a homograft, but follow-up data are too preliminary to develop recommendations at this time (1998). To offer these patients a hopefully last operation, a mechanical valve is a viable option in our opinion. Until recently [15] there was almost no support for this strategy in the literature, on the contrary, implantation of mechanical valves is advised against because of hearsay evidence of pulmonary thrombo-embolic complications. By reviewing the very scarce literature (Table 1) on mechanical pulmonary valvar replacement we conclude that only few series are reported and that those studies were hardly more than case histories, except for a few. We conclude that there is insufficient evidence against the use of mechanical pulmonary valvar prostheses, although the experimental work of Kiyota et al. [10] must be taken into account. This study reports in vitro experiments on leaflet closure of mechanical bileaflet valves in low-pressure circumstances and conclude that forces in the pulmonary system are insufficient to close both semi-discs at all times and that as a result pulmonary regurgitation remains, in this experimental setting. Although the authors advocate in vitro assessment of mechanical valves in a low-pressure system, we could not find any subsequent report on these views. On the contrary, our clinical echocardiography studies did not show any evidence of regurgitation of the mechanical valvar prosthesis, apart from the normal early diastolic jets that also can be seen after placement of a mechanical valve in the aortic position.
The drawback of the need for anticoagulation is counterbalanced by the prospect of the likely absence of re-operations due to valve malfunction as compared to biological valvar substitutes. Both risks, however, are unequal in nature and in time, for which reason they need to be described carefully.
The reported freedom from reoperation of allografts in the right ventricular outflow tract varies in different papers. The most favourable figures are 89% actuarial freedom from reoperation at 10 years and 80% at 20 years [17]. Other papers report 81% at 5 years and 70% at 7 years [6]. Second and third replaced allografts fare worse [5], so that the interval between reoperations becomes shorter over time. Preservation techniques of allografts and subsequent rejection-like phenomena play a role, as yet not fully elucidated [18]. Multiple re-operations are to be anticipated in this strategy, when taking the otherwise good life expectancy of these patients into account, a prospect most patients do not relish.
Xenografts can also be used in the right ventricular outflow tract, and have a reported 10-year survival of 85% [7]. Essentially, xenografts have the same drawback as allografts do, resulting in multiple reoperations. Furthermore, one has to bear in mind that patients most likely become increasingly symptomatic for a considerable period before yet another reoperation is performed.
The risk of thrombo-embolic and bleeding complications in patients on oral anticoagulant therapy for mechanical heart valves has been thoroughly analysed by Cannegieter et al. [19]. The linear risk of cerebral emboli was 0.68 per 100 patient-years, whilst the risk of peripheral emboli was much lower at 0.03 per 100 patient-years; most likely due lack of detection of the latter. These embolic risks must theoretically be similar for pulmonary mechanical valvar prostheses. The emboli of the size causing a disabling cerebro-vascular accident, cause only a minor pulmonary embolus, possibly even of a subclinical nature. Thus, the embolic risk of a mechanical pulmonary valvar prosthesis seems to be slight. The risk of thrombosis of the valve must also be minimal when anticoagulation is adequate. Whether or not the immobilised valve that we replaced in our current series of patients is due to fibrosis secondary to a thrombotic process is a matter of speculation. Most likely, however, by the very nature of the pathology it was excessive fibrosis that was induced by the vascular prosthesis that was used to cover the valve and the outflow tract.
Bleeding complications in the Cannegieter paper [20], whether intracranial or spinal, were reported to be 0.57 per 100 patient-years. In contrast, the risk of major extracranial bleeding was more than three times larger at 2.1 events per 100 patient-years. The patients in this study had a target INR of 3.64.8. Patients younger than 50 years had a very low risk of thrombo-embolic event 0.1 per 100-patient years. In this study, however, there were no patients with a mechanical valve in the pulmonary position.
Patients with an allograft or xenograft therefore have an estimated risk of reoperation of 1520% at 10 years [20,7], an interval that is expected to decrease. Since our patients had a median age of 33 years at the time of their PVR, and assuming a normal life expectancy, 4560% of them will need multiple reoperations, each time associated with a mortality risk of 210%. In contrast, patients with a mechanical valve have a risk of reoperation of 4% at 14 years (this study) and have a cumulative reoperation risk during their lifetime of 8%.
It is difficult to compare these risks because of their disparate nature. In our opinion both circumstances, mechanical PVR and allograft-PVR or xenograft-PVR, probably do not differ in the incidence of complications, but do in mode of complication. Where patients that need re-do operations risk mortality, even more then once, patients that use anti-coagulant medication suffer more from morbidity, albeit during their entire lifetime. Furthermore, we do realise that fatal thrombo-embolic or bleeding complications do occur occasionally. In fact our only late death until now occurred of a major pulmonary bleed due to coumadine over dosage.
Anticoagulant therapy is thus an important issue. Most of the reports advising against the use of mechanical valves mention either no anticoagulant therapy or inadequate prophylaxis such as aspirin or aspirin and dipyramidol. Only those studies that employ coumadine anticoagulant therapy, maintaining an INR of more than 2.0, report absence of thrombo-embolic incidents. As is the case with every other use of mechanical valves adequate anti-thrombotic therapy is mandatory. We advocate maintaining an INR of 2.54.0. In this respect there is no restriction to self-management of the level of anticoagulation. Finally, it is not only speculation that well-trained patients control their INR level better than health professionals or specialised laboratories do [21].
| 5. Conclusion |
|---|
|
|
|---|
| Appendix A |
|---|
|
|
|---|
Dr B. Maruszewski (Warsaw, Poland): My comment is that, what is the choice nowadays for the pulmonary valve replacement? You have xenograft, you have allograft, you have mechanical valve. If we all believe that homogenous tissue will calcify, so we provide patient with second operation in the future, there is still a choice between the mechanical valve, but also the new generation of xenografts, the valves that are covered with the agents that reduce the calcification.
So this is my comment. And actually I have to say I never put the mechanical valve in the right ventricle outflow tract and Im not prepared to do it. But what we have done, we have switched from about 800 homografts, that we put in this position in the past, to the freestyle valve, since Magdi Yacoub has reported very good long-term results, and there is no reason why we should not use this valve on the right side of the heart. And there is a report that was presented on the CHHS meeting in Buenos Aires that over 80 of these valves have already been implanted. So I think having in mind the anticoagulation and the risk of complications, I think we should really consider this valve as the other choice.
Dr Waterbolk : I like to comment on the use of xenografts. Every time newer generations of these valves are presented, but it has to be seen how they will last in the end. And furthermore these patients have a long time to live assuming a normal life expectancy.
Dr B. Murzi (Massa, Italy): I would like to know, first, which kind of valve you used, monocusp or bileaflet valve?
Dr Waterbolk : All these valves are bileaflet valves.
Dr Murzi : I have seen that you presented the paper that was from Milan. And we did that paper and we observed that in the literature most of the valve that thrombosed were the bileaflet valves that had four struts. And there were no reports of tilting valve that was in the pulmonary position. So we are using, when we have to put a mechanical valve on the right ventricle of inflow tract, we use tilting valve because of that.
And I totally agree with you that when you have a patient that has been operated five or six times, probably deciding to have a valve that can last for all the life could be a good idea.
Dr Waterbolk : Well, this series shows that the bad reputation of the bileaflet valve is, as far as we are concerned, not right.
I like to make another comment. We give the patients themselves the opportunity to think over the prospect of redo operations or the prospect of lifelong anticoagulation and let them decide themselves.
| Footnotes |
|---|
Presented at the joint 19th Annual Meeting of the European Association for Cardio-thoracic Surgery and the 13th Annual Meeting of the European Society of Thoracic Surgeons, Barcelona, Spain, 2528 September 2005. | References |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
M.G. Hazekamp Editorial comment A mechanical prosthesis for pulmonary valve replacement? Eur. J. Cardiothorac. Surg., July 1, 2006; 30(1): 33 - 34. [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||