EJCTS Click here to go to Siemens website
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Eur J Cardiothorac Surg 2008;33:944. doi:10.1016/j.ejcts.2008.02.017
Copyright © 2008, European Association for Cardio-thoracic Surgery. Published by Elsevier. All rights reserved.

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Google Scholar
Right arrow Articles by Jung, K.
PubMed
Right arrow Articles by Jung, K.
Related Collections
Right arrow Transplantation - heart


Letters to the Editor

Matrix metalloproteinases do not properly work as peripheral blood biomarkers without taking into account the preanalytical impact of blood sampling

Klaus Jung*

Department of Urology, University Hospital Charité, Schumannstrasse 20/21, D-10117 Berlin, Germany

Received 23 December 2007; accepted 13 February 2008.

* Corresponding author. Tel.: +49 30 450 515041; fax: +49 30 450 515904. (Email: klaus.jung{at}charite.de).

Key Words: Matrix metalloproteinases • Blood sampling procedure

I read with great interest the article by Aharinejad et al. [1]. The authors measured matrix metalloproteinases (MMP) 1, 8, and 9 and tissue inhibitor of metalloproteases 1 (TIMP-1) in the serum of heart transplant recipients during the first year after cardiac transplantation at different time intervals. The changed serum concentrations of these analytes following cardiac transplantation were interpreted as possible consequences of allograft damage due to ischemia–reperfusion injury or acute and chronic rejections, respectively. However, the aim of this Letter to the Editor is to address the attention of the reader on a basic pitfall that was obviously overlooked by Aharinejad et al. [1] when they designed and performed their study.

My concerns refer to the well-known impact of blood sampling procedure that has been repeatedly demonstrated as important preanalytical interfering factor in measuring the true concentrations of circulating MMPs and TIMPs in peripheral blood [2,3]. Serum collected either with or without clot activator generally show higher concentrations of MMP-1, MMP-8, MMP-9, and TIMP-1 compared with concentrations of corresponding analytes measured in plasma samples collected with citrate or heparin as anticoagulants. That effect is additionally influenced by the time interval between blood collection and centrifugation of the blood specimen [2]. Aharinejad et al. [1] used serum instead of plasma for their measurements. Moreover, they did not give any details of the serum sampling procedure, neither the type of serum collected with or without clot activation nor the time intervals between venipuncture and centrifugation of samples were explained.

Citrate plasma has been recommended as sample of choice to measure true circulating MMPs in blood [3,4]. Considering the concentrations in citrate plasma as reference, the concentrations of the above-mentioned MMPs were shown in our own experiments 20–30-fold higher in serum collected with clot activator as generally applied in clinical practice. Platelets and leukocytes contain abundant amounts of these components [3]. It explains that there are high background levels in serum due to the release of these analytes from platelets and leukocytes depending on the blood sample preparation with and without clot activator. Thus, serum concentrations do not certainly correspond to the true concentrations of circulating components in peripheral blood. The misinterpretation of MMP measurements in serum compared with determinations in plasma samples was recently proven [5]. It can be assumed that the failure to take into account the effect of sample preparation on the measurement of MMPs during the follow-up study as done by Aharinejad et al. [1] could not be avoided by a consistent use of serum samples.

In conclusion, the study of Aharinejad et al. [1] clearly exemplified the basic principle that reliable preanalytical conditions for the measurement of biomarkers have to be ascertained before the diagnostic validity of the markers should be explored in clinical trials. From this point of view, it would be advisable to re-evaluate the data of Aharinejad et al. [1].

References

  1. Aharinejad S, Krenn K, Zuckermann A, Schafer R, Paulus P, Seebacher G, Wolner E, Grimm M. Matrix metalloproteases and their tissue inhibitor in cardiac transplantation. Eur J Cardiothorac Surg 2007;32:48-51.[Abstract/Free Full Text]
  2. Jung K, Meisser A, Bischof P. Blood sampling as critical preanalytical determinant to use circulating MMP and TIMP as surrogate markers for pathological processes. Int J Cancer 2005;116:1000-1001.[CrossRef][Medline]
  3. Mannello F, Tonti GA. Gelatinase concentrations and zymographic profiles in human breast cancer: matrix metalloproteinases circulating in plasma are better markers for the subclassification and early prediction of cancer: the coagulation/fibrinolysis pathways alter the release, activation and recovery of different gelatinases in serum. Int J Cancer 2007;121:216-218.[CrossRef][Medline]
  4. Makowski GS, Ramsby ML. Use of citrate to minimize neutrophil matrix metalloproteinase-9 in human plasma. Anal Biochem 2003;322:283-286.[CrossRef][Medline]
  5. Wu CY, Wu MS, Chiang EP, Chen YJ, Chen CJ, Chi NH, Shih YT, Chen GH, Lin JT. Plasma matrix metalloproteinase-9 level is better than serum matrix metalloproteinase-9 level to predict gastric cancer evolution. Clin Cancer Res 2007;13:2054-2060.[Abstract/Free Full Text]



This article has been cited by other articles:


Home page
Eur. J. Cardiothorac. Surg.Home page
S. Aharinejad
Reply to jung.
Eur. J. Cardiothorac. Surg., May 1, 2008; 33(5): 945 - 945.
[Full Text] [PDF]


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Google Scholar
Right arrow Articles by Jung, K.
PubMed
Right arrow Articles by Jung, K.
Related Collections
Right arrow Transplantation - heart


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS