Department of Cardiovascular Surgery, University Hospital CHUV, Rue de Bugnon 46, 1011 Lausanne, Switzerland
* Corresponding author. Tel.: +41 26 426 7185; fax: +41 26 426 7314. (Email: martyb{at}h-fr.ch).
The long-term impact of implanting stentgrafts on the behavior of growing arteries is still not fully understood. The ability of the aorta in its growing phase to react to and repair injuries induced by an implanted stentgraft makes this a unique and special area of research. Typically, a stented aortic segment containing either a bare stent or a stentgraft will develop stenosis, while the adjacent non-stented aortic segments grow and increase to their normal size and function as demonstrated by Siegenthaler et al. [1]. In clinical settings, stenting of aortic coarctation in adolescents usually requires redilation compensating for growth to avoid stenosis. Currently, the challenge facing stent and stentgraft design is the ability to adapt their geometries to the potentially large increase in the aortic dimensions over time.
In analyzing stentgraft performance in growing arteries, two key factors have to be considered; luminal area and wall thickness. First, the luminal area, and indeed not the diameter itself, is crucial for the aortic function in directly determining flow and should be used as the reference metric. The luminal area in a growing aorta is ultimately determined by the nominal area of the stentgraft minus the area of intimal hyperplasia. Stentgrafts have to be oversized by 10–20% to give sufficient frictional force to prevent migration at implantation. However, moderate oversizing might not be enough to match the ultimate adult aortic dimensions. By studying the performance of highly oversized self-expandable stentgrafts we noticed them compensating for some aortic luminal narrowing, thereby minimizing the effect of intimal hyperplasia [2]. Yet a moderate stenosis of 30–60% of the aortic area persisted. While high oversizing seems beneficial for the long-term performance of stentgrafts, they should have a minimal profile at implantation when constrained in a relatively small aorta. Highly oversized stentgrafts in a growing aorta can have folds of the fabric resulting in a large profile. We noticed that intimal hyperplasia optimizes flow characteristics by filling up folds creating a smooth circular lumen, yet the luminal area becomes smaller increasing the degree of stenosis. We do not yet know if these stentgrafts can fully expand to their nominal area by repeated dilations.
The second factor in the analysis of stentgraft incorporation in the context of growth is aortic wall thickness. While deploying a stengraft, blood is trapped between the device and the aorta, and the resulting clot becomes embedded with fibroblasts. This layer is commonly referred to as the interface, and can be substantial in the folds of the stentgraft fabric, while practically absent underlying the stent struts, which become embedded into the tunica media by the radial force of the stent itself and pulsation pressure. Within the stented area the thickness of the aortic wall is mainly composed of intimal hyperplasia including the protruding folds of the fabric with consecutive luminal narrowing. This underlines the importance of low profile devices. The fate of the tunica media underlying the device is currently unclear, yet medial thinning has been observed. Since the medial layer varies considerably, only measurements of its area are reliable. However, as long as the stentgraft remains implanted, the thickness of the media may well be irrelevant.
The experimental setting of aortic growth with its high reparative potential towards injury is not comparable to the clinical setting of dilatative arteriopathy in adult or elderly individuals, with their minimal capacity for integration of a stentgraft into the aortic wall. In the growing aorta, the interface itself, fixes and seals the device to the aortic wall, and in this context, the term endoleak should be avoided.
The study by Siegenthaler et al. supports the view that as endovascular surgery evolves, the interaction between relatively rigid stentgrafts and growing arteries should be a topic of further research in order to develop highly adaptable devices to ensure initial as well as sustainable long-term performance.
| References |
|---|
|
|
|---|
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |